position Home > JJ Products > Engineering plastics and products testing machines > Melt Flow Indexer
Melt Flow Indexer
熔体流动速率仪
MFI-2322S Melt Flow Indexer
This instrument is used to test the engineering plastics such as polyethylene, polysulfone, fluoroplastics and nylon with high melting temperature, as well as plastics with low melting temperature such as polyethylene, polystyrene, polypropylene ABS resin and polyformaldehyde resin.

Standard

GB/T 3682.2,GB/T 3682.1,GB/T 18742.2,ASTM D 1238,ISO 1133-1
Description
Features
Standards
Specifications
Accessories

MFI-2322S


Melt flow rate indexer




This instrument is used to measure the melt flow rate of various polymers in viscous flow state. It is not only applicable to engineering plastics such as polycarbonate, polysulfone and fluoroplastics with high melting temperature, but also applicable to plastics with low melting temperature such as polyethylene, polystyrene, polypropylene, ABS resin and polyformaldehyde.

1. The temperature control system of the tester has fast heating speed, high constant temperature accuracy, short temperature recovery time after filling, and can quickly return to constant temperature within 2min; Temperature control is stable and reliable.





2. The system automatically identifies the effective test range of national standard, ISO standard and American Standard.

3. The control software can realize the functions of parameter setting, constant temperature control, cutting, metering calibration, automatic weight loading, timing, MVR result display, etc.





4. When using MVR, the MVR value of the sample at the specified time can be measured. After weighing the sample, the system automatically obtains the MFR value, which can be compared with the test results of MFR.



5. The system has the function of test parameter storage, and can store 8 groups of test parameters.

6. The measured results can be automatically transformed into each other, with the function of melt density test, and equipped with automatic weight loading device.



Standard
GB/T 3682.1-2018
GB/T 3682.2-2018
ISO1133-12011
ISO1133-22011
JB/T 5456-2016
ASTM D 1238-10

MFI-2322S



Technical Parameter

Technical Parameter



Test methods:
MFR/MVR
Display mode:
Full color touch screen
Loading method:
Motorized
Measuring range:
(0.1 - 100)g/10min (0.01 - 350)cm³/10min

Temperature control range:



(50 - 450)℃

 


Temperature display

resolution:


0.01



Timing accuracy:
0.01S
Displacement accuracy:

±0.02mm